RS507 2D barcodes in SSI mode

When using a Ring Scanner Motorola-Zebra RS507 (Bluetooth) in SSI mode with WireLess TelNet to read 2D barcodes, it is needed to activate the 2D barcode options AND activate de AZTEC and QRCODE option (Opt=1) [SCANNER] Enable=Yes Reader=2 and [CODES_2D] On=Yes Min=2 Max=100 Prefix= Suffix= Opt=1

RS507 UCC-EAN Barcodes SPP

When using an RS507 Bluetooth Ring Scanner with in SPP mode (Scan Serial) WireLess TelNet VT or 5250 the default configuration file uses any control character as barcode terminator. Some UCC-EAN barcodes may contain control characters inside as variable field separator (Like 0X1A, 0X1B, 0X1C, 0X1D). These control characters will act as terminator, so the barcode is… read more »

Run specific configuration

WireLess TelNet can be run with a command line containing arguments to run a specific configuration file folder (profile). WTn.exe CONFIG=Application\MyProfile Will run WireLess TelNet VT and load the configuration files from the specified location.

Create a Telnet capture

If you need to send a file integrating TelNet Frame you can create a TelNet capure with WireLess TelNet VT and 5250. Active the “capture mode” here : After this , all of your frame are captured and stocked in a WTnXX.tnst file created in ROOT directory on your terminal. .TNST file can be read with ScreenTracker… read more »

Different Cursor states

Below you will find the different cursor states in a Wireless TelNet session. A key combination is the cause of this change of state:   Normal State :   Alpha State :   Function State :   Control State  :     Control + ALT State :

AutoRunProfil

It’s possible to automatically launch a program based on the selected profile in the telnet. To do this you must create a file named : AutoRunProfil.txt in that file choose the program run as follows exemple : \windows\regmerge.exe|/Q “\Application\WTnVT\Beep_Volume_Voice.reg” \windows\cmd.exe|/Q “\application\WTn52\exemple.bat” Copy and past the AutoRunProfil.txt file in the profil directory. The .reg files are… read more »

SendHostBel / RS507

There is an option in the Telnet configuration allowing the RS507 scanner to emit “beeps” like that : check out the following document : (FR/PDF) Faire “beeper” la RS507 dans une session TelNet

Patch ScanAssoc 1.1.3

Here you can find the last version of ScanAssoc (1.1.3) coming with Wireless TelNet VT and 5250 in version 4.5.9. If you have a older version of WirelessTelNet you can download it and replace the executable directly in your PDA LINK TO DOWNLOAD

Extra characters displayed at connection time with GEROGIA SOFTWORKS

The Telnet server GEORGIA SOFTWORKS may not send the right command “IAC SB TT SN IAC SE” for TREMINAL TYPE request (6 bytes). And sends “IAC SB TT SN” instead (4 bytes). That would generate extra unattended characters in display. A workaround is done in V459-2 WTnVT build.

Turn display for High Visibility

If the PDA is used in outdoor operation under sunlight the display will be not easy to read. It will be needed to change standard colors to increase text visibility. I/e white background with black text. DisplayMono forces the display color ignoring any host commands for text color. DefFrgColor and DefBkgColor defines the text and background… read more »